PDF(468 KB)
Analysis of portal vein variations by 64slice spiral CT and clinical application
GUO Cheng-wei,LIANG Wen,QUAN Xian-yue,et al.
Chinese Journal of Practical Surgery ›› 2008, Vol. 28 ›› Issue (08) : 641-643.
PDF(468 KB)
PDF(468 KB)
Analysis of portal vein variations by 64slice spiral CT and clinical application
Objective:To analyze variations of main trunk of portal vein (MTPV) in healthy persons by multislice spiral computed tomography portagraphy (MSCTP). Methods:Four hundreds and five subjects (including 200 normal volunteers)were performed by test bolus to demonstrate the optimization of MSCTP from December 2006 to June 2007 at the Affiliated Zhujiang Hospital of South Medical University.The maximum intensity prejection (MIP),volume rendering (VR) and multiplanar reformation (MPR) were employed for threedimensional reconstruction to analyze variations of MTPV (1~3 grades). Results:There were 12 types of MTPV (1~3 details) with the variation rate of 2074%. Conclusion:Due to high variation rate of portal vein among normal people,the 3-D reconstruction of multislice CT is constructive to local the focus and the decision of approaches for the surgical treatment in clinic.
/
| 〈 |
|
〉 |