Abstract:
Objective To evaluate the bond strength of two-base brackets ,analyse the bracket base remnant and the effect on enamel surface after brackets were removed. Methods The laser-structured base(n = 20)and cast-structured base(n = 20)brackets were bonded on the surfaces of extracted maxillary premolars and the SBS,TBS tested. Premolar brackets were from patients who finished orthodontic treatment (laser-structured base,n = 71;cast- structured base,n = 71). ARI was recorded in all bracket bases and some bases were chosen randomly and analysed by scanning electron microscope(SEM). Results The SBS and ARI of laser-structured base brackets were higher than cast-structured base brackets,but the TBS was lower(P < 0.05). Each bracket base remnant was found to have Ca element. Conclusion The bond strengths of the two brackets are enough for clinical application;enamel damage occurs during removing.
Key words: bracket base;bond strength;adhesive remnant index, ARI;enamel damage
摘要:
目的 比较激光和铸造2种底板托槽的粘接强度,分析托槽底板残余物,探讨拆除托槽对釉质表面的影响。方法 选取2014年6月于哈尔滨医科大学口腔颌面外科因正畸拔除的上颌前磨牙40颗,其中选择激光底板和铸造底板托槽各20颗,粘接于离体上颌前磨牙后进行剪切、拉伸实验。再选取正畸结束患者拆除的前磨牙激光底板、铸造底板托槽各71个,对所有托槽底板粘接剂残余指数(ARI)进行计分,并随机抽取托槽进行底板粘接剂电镜观察。结果 激光底板托槽抗剪切强度(SBS)和ARI高于铸造底板托槽,抗拉伸强度(TBS)低于铸造底板托槽(P < 0.05);托槽底板残余粘接剂中均可检测到钙元素。结论 激光和铸造两种底板托槽的粘接强度均能达到临床要求,拆除托槽对釉质表面有损伤。